Beryllium Contaminated Scissor Lift Used for Several Years before Discovery
7386 Views
Feedback
0 Comments

Favorite
Image for Beryllium Contaminated Scissor Lift Used for Several Years before Discovery

Type:  Lessons Learned

Publisher:  Washington Closure Hanford, Richland, WA

Published As:  Public

Date: 

Topics:  Biological Safety, Occupational Safety and Health, Quality Assurance, Radiation Protection

On September 22, 2015, unexpected Alpha and Beryllium contamination was found on a scissor lift during a preventative maintenance inspection. Debris found on the unit was uncharacteristic of work performed in the area of use. The lift, acquired from Rocky Flats several years ago, had been in regular use since its acquisition in radiological and industrial hygiene controlled areas. The response to the discovery of unexpected contaminants was appropriate however, considering the equipments history of use, greater attention should have been paid when the equipment was first acquired.

Lessons Learned: Equipment obtained from other DOE sites should be thoroughly inspected for potential contamination, including asbestos contamination, prior to use.

You must be logged in to open the attachment.

Download Article
Comments about this Article
You must be logged in to add or view comments.
Related Articles
Feedback Form
How did you apply this information?
You must be logged in to use this feature
Is this article applicable to your organization?